Function | Testing item | Value | Accuracy | Unit | Remark |
Charging Voltage | Rated charging voltage | 85 | ±0.25 | (V) | Parameters can be set |
Constant current | Maximum charging current | 60 | \ | (A) | Recommended value |
| Maximum discharging current | 60 | \ | (A) | Recommended value |
Charging protection | Overcharge protection voltage | 4250 | ±25 | (mV) | Parameters can be set |
| Overcharge protection delay | 1000 | ±500 | (mS) | Parameters can be set |
| Overcharge protection recovery voltage | 4120 | ±50 | (mV) | Parameters can be set |
| Overcharge protection recovery conditions | The voltage of each cell is lower than the overcharge recovery voltage |
| Charging overcurrent protection | 60 | ±5 | (A) | Parameters can be set |
| Charging overcurrent protection delay | 10000 | ±1000 | (mS) | Parameters can be set |
| Charging overcurrent protection recovery conditions | Disconnect charger |
Discharging protection | Over discharge protection voltage | 2800 | ±80 | (mV) | Parameters can be set |
| Over-discharge protection delay | 1000 | ±500 | (mS) | Parameters can be set |
| Over-discharge protection recovery voltage | 2900 | ±100 | (mV) | Parameters can be set |
| Over-discharge protection recovery conditions | After 16 seconds of over discharge, it enters sleep mode and needs to be activated by inserting a charger. The voltage of each cell is higher than the recovery voltage (insert charger) |
| Discharge overcurrent protection | 120 | ±5 | (A) | Parameters can be set |
| Discharge overcurrent protection delay | 500 | ±200 | (mS) | Parameters can be set |
| Short circuit protection | Yes | (A) | Parameters can be set |
| Short circuit protection delay | 300 | ±200 | (uS) | Parameters can be set |
| Overcurrent/short circuit protection delay recovery bar | Disconnect load |
Temperature protection | Charging high temperature protection | 55 | ±5 | (℃) | Parameters can be set |
| Charging high temperature protection recovery | 45 | ±5 | (℃) | Parameters can be set |
| Charging low temperature protection | -10 | ±5 | (℃) | Parameters can be set |
| Charging low temperature protection and recovery | -5 | ±5 | (℃) | Parameters can be set |
| Discharge high temperature protection | 75 | ±5 | (℃) | Parameters can be set |
| Discharge high temperature protection recovery | 60 | ±5 | (℃) | Parameters can be set |
| Discharge low temperature protection | -20 | ±5 | (℃) | Parameters can be set |
| Discharge low temperature protection recovery | -15 | ±5 | (℃) | Parameters can be set |
Self-consumption | Single cell self-consumption | 43 | ±10 | (℃) |
|
IR | Charge/discharge circuit IR | 3 | ≦30 | (mΩ) |
|
Dimension | L*W*H | 150*80*16 | (mm) |
|
Charging operating temperature | Charging operating temperature | -20~+80 | (℃) |
|
Discharge operating temperature | Discharge operating temperature | -20~+80 | (℃) |
|
Working humidity | Working humidity | +10~+80(@40℃) | (%RH) |
|
Storage temperature | Storage temperature | -25~+85 | (℃) |
|
Storage humidity | Storage humidity | +10~+80(@40℃) | (%RH) |
|